Reference Files

The spectral_leak step uses the MRSPTCORR reference file.

MRSPTCORR reference file

REFTYPE:

MRSPTCORR

Data models:

MirMrsPtCorrModel

The MRSPTCORR reference file contains parameter values used to subtract the MRS 12 micron spectral leak in the spectral leak step. It also contains parameters to correct point sources, in future enhancements, for across-slice corrections and throughput variations.

Reference Selection Keywords for MRSPTCORR

CRDS selects appropriate MRSPTCORR references based on the following keywords. MRSPTCORR is not applicable for instruments not in the table.

Instrument

Keywords

MIRI

INSTRUME, EXP_TYPE, DATE-OBS, TIME-OBS

Standard Keywords

The following table lists the keywords that are required to be present in all reference files. The first column gives the FITS keyword names. The second column gives the jwst data model name for each keyword, which is useful when using data models in creating and populating a new reference file. The third column gives the equivalent meta tag in ASDF reference file headers, which is the same as the name within the data model meta tree (second column).

FITS Keyword

Data Model Name

ASDF meta tag

AUTHOR

model.meta.author

author

DATAMODL

model.meta.model_type

model_type

DATE

model.meta.date

date

DESCRIP

model.meta.description

description

FILENAME

model.meta.filename

N/A

INSTRUME

model.meta.instrument.name

instrument: {name}

PEDIGREE

model.meta.pedigree

pedigree

REFTYPE

model.meta.reftype

reftype

TELESCOP

model.meta.telescope

telescope

USEAFTER

model.meta.useafter

useafter

NOTE: More information on standard required keywords can be found here: Standard Required Keywords

Type Specific Keywords for MRSPTCORR

In addition to the standard reference file keywords listed above, the following keywords are required in MRSPTCORR reference files, because they are used as CRDS selectors (see Reference Selection Keywords for MRSPTCORR):

Keyword

Data Model Name

EXP_TYPE

model.meta.exposure.type

MIRI Reference File Format

The MIRI MRSPTCORR reference files are FITS format, with 5 BINTABLE extensions. The FITS primary data array is assumed to be empty. The format and content of the MIRI MRSPTCORR reference file

EXTNAME

XTENSION

Dimensions

LEAKCOR

BINTABLE

TFIELDS = 3

TRACOR

BINTABLE

TFIELDS = 7

WAVCORR_OPTICAL

BINTABLE

TFIELDS = 6

WAVCORR_XSLICE

BINTABLE

TFIELDS = 2

WAVCORR_SHIFT

BINTABLE

TFIELDS = 3

The formats of the individual table extensions are listed below.

Table

Column

Data type

Units

LEAKCOR

WAVELENGTH

float

micron

FRAC_LEAK

float

N/A

ERR_LEAK

float

N/A

TRACOR

CHANNEL

int

N/A

WAVE_MIN

float

micron

WAVE_MAX

float

micron

T_WMIN_CENTRE

float

percent

T_WMIN_EDGE

float

percent

T_WMAX_CENTRE

float

percent

T_WMAX_EDGE

float

percent

WAVCORR_OPTICAL

SUB_BAND

string

N/A

BETA_SLICE

float

arcsec

WAVE_MIN

float

micron

WAVE_MAX

float

micron

SRP_MIN

float

N/A

SRP_MAX

float

N/A

WAVCORR_XSLICE

XSLICE_MIN

float

micron/arcsec

XSLICE_MAX

float

micron/arcsec

WAVCORR_SHIFT

BETA_OFF

float

slice

DS_MIN

float

slice

DS_MAX

float

slice

This reference file contains the relative spectrophotometric response function for the MRS 12 micron spectral leak, along with tables of across-slice wavelength and throughput variations for point sources in each of the MRS bands. Currently, only the LEAKCOR table is use in the jwst pipeline.